Master'sOpen Access

Energy and exergy analysis of heat pump drying system using heat pipe heat recovery exchanger

2022
0 views
0 downloads
Advisor: Prof. Salih Coşkun ; Doç. Dr. Cüneyt Tunçkal

Abstract (EN)

In this study, an external condenser operating in series with the internal condenser is used. heat pipe heat return to a heat pump assisted drying (IPK) system with The recovery exchanger (IBIGKE) was installed and investigated experimentally. Next to the IBIGKE, the activation of the external condenser The effects on performance and drying time were investigated. Also, the system By performing energy and exergy analysis, system performance is determined for each The exergy efficiencies and losses of the element were calculated. Experiments were performed using quince slices at 40 °C and 3,5 m/s drying time. speed was carried out.

Author

Buğra Hezer

How to Cite

Buğra Hezer (Master Thesis). Energy and exergy analysis of heat pump drying system using heat pipe heat recovery exchanger, 2022, Bursa Uludağ Üni̇versi̇ty.

License

Tüm Hakları Saklıdır

This work is shared under the specified license terms.

More theses from Bursa Uludağ Üni̇versi̇ty