Histopathological, histomorfometrical, immunohistochemical and tomographical evaluation of the changes in bone by loading of mini-screw
2012
0 görüntülenme
0 i̇ndirme
Danışman: Prof. Dr. Nilüfer Darendeliler
Özet (EN)
The aim of this study is histopathological, immunohistochemical, histomorphometrical and mikro-tomographical evaluation of the changes observed in the rabbit tibia bone by the application of mini-screws with different geometry and diameter.In this study eighteen adult male rabbits are used. Cylindrical mini-screws of diameter 1.5 mm (designated as A), conical mini-screws of diameter 1.5 mm (B), conical screws of diameters 1.4 mm (C) and 1.6 mm (D) with fine-pitch threads close to screw head, were inserted in rabbit tibia. The mini-screws were inserted to the right tibia bone by recording the applied torque. Ni-Ti coil-springs that are arranged to apply 1 N force were attached between the mini-screws. The rabbits were sacrificed at the end of the 1st, 3rd and 5th weeks. Then the mini-screws were removed by measuring in the torque values and the bone has been evaluated histopathologically, histomorphometrically, immunohistochemically (RANK and OPG) and micro-tomographically.Compared with conical B, C and D mini-screws, cylindrical A mini-screws were delayed bone healing at the end of 1st, 3rd and 5th weeks and removal torque values of A mini-screws were found lower. At the end of the first week RANK immunoreactivity in B mini-screws and OPG immunoreactivity in C mini-screws were observed. At the end of 3rd and 5th weeks an increase in OPG immunoreactivity were recorded in the bone for the cases where B, C, D mini-screws have been applied. Best bone healing and osteoblastic activity were observed in the bone by the use of C and D mini-screws and higher removal torque values were also recorded for these cases. D mini-screws with wider diameter required higher removal torque values than C mini-screws.It is observed that conical with fine-pitch threads close to screw head, were more stable and it is found that stabilization increases with increasing diameter.
Yazar
Dr. Orhan Salmanlı
Bu Yayına Nasıl Atıf Yapılır
Orhan Salmanlı (Doctorate thesis). Histopathological, histomorfometrical, immunohistochemical and tomographical evaluation of the changes in bone by loading of mini-screw, 2012, Gazi University, Diş Hekimliği Bölümü.
Anahtar Kelimeler
Lisans
Tüm Hakları Saklıdır
Bu eser belirtilen lisans koşulları altında paylaşılmaktadır.
Gazi University tezlerinden daha fazlası
- Occupational accident analysis and modelling in oil and gas drilling sector Turkey(2021)
- The use of verbal memory in the context of sustainability and power at the museums of Turk(2010)
- XVI. yüzyıl Anadolu'sunda Oğuzların Karkın Boyu(2004)
- Sharing of real life geometry samples via a social learning environment: A case study(2021)
- Evaluatıon of calcium hydroxide removal efficiency of two different irrigation activation techniques from artificial internal resorption cavities prepared at different root levels(2021)
- Experimental development of the interfacial bond-slip model between textile reinforced mortar strips and masonry walls(2025)