Evaluation of products that may cause false positivities in breath alcohol test
2022
0 görüntülenme
0 i̇ndirme
Danışman: Dr. Öğr. Üyesi Kenan Kaya
Özet (EN)
Introduction and objective: It is known that driving under the influence of alcohol paves the way for traffic accidents, causes material and moral losses as well as many injuries and deaths. One of the measures taken to prevent the use of drunk driving is alcohol inspections carried out in traffic. In these inspections, breathalyzer devices that detect the alcohol level from the breath are used due to ease of use. However, sometimes there may be objections to measurements made with the alcohol meter and the matter is referred to the judicial authorities. However, sometimes there may be objections to the measurements made with the breathalyzer and the issue is referred to the judicial authorities. It is known that there are points to be considered in order to get accurate results from these devices. In this study, it is aimed to examine the products that may affect breath alcohol testing and the relationship of these effects with time. Materials and methods: An experimental study was conducted involving 30 healthy volunteers with 33 different products that we think may affect yhe breath alcohol level. Breath alcohol analysis was performed via the breathalyzer device at the first minute after the use or consumption of the products. In case of a positive measurement result, the measurement was continued at two-minute intervals until the alcohol value detected in the breath was zeroed. Results: In the measurements made after the consumption of organic grapes, pomegranate, orange juice and tangerine fizzy drinks, a positive measurement result was encountered only in the first minute. Positive measurement results were observed, which continued by decreasing until third minute after the consumption of turnip juice, up to fifth minute after the use of hand sanitizers, up to seventh minute after the use of cologne and up to the eleventh minute after the use of alcohol-containing mouthwashes. The maximum values measured in the first minute are 4.90 permille in mouthwashes, 1.96 permille in hand sanitizers, 2.76 permille in cologne and 0.32 permille in beverages. No alcohol was detected in the respiratory air in the measurements made after testing toothpastes, non-alcoholic mouthwashes, fizzy drinks, cola, orange fizzy drink, ayran, kefir, gum and sugar with menthol, organic apple juice and mixed fruit juices. Conclusion: In the breath alcohol test, positive measurement results were encountered in people who were known not to consume alcoholic beverages but used alcoholic products or consumed some foods. By making measurements after a certain period of time for people who state that they use or consume these products, erroneous sanctions to be applied due to these errors and unnecessary workload will be prevented by avoiding these false positive results.
Yazar
Dr. Büşra Deniz
Bu Yayına Nasıl Atıf Yapılır
Büşra Deniz (Medical Specialty Thesis). Evaluation of products that may cause false positivities in breath alcohol test, 2022, Çukurova University.
Anahtar Kelimeler
Lisans
Tüm Hakları Saklıdır
Bu eser belirtilen lisans koşulları altında paylaşılmaktadır.
Çukurova University tezlerinden daha fazlası
- Subalgebras of free associative algebras(2018)
- Production and characterization of ZnO/Cu2O based devices growing with spin coating method(2019)
- Effect of rations containing black pepper (Piper nigrum) and curcuma (Curcuma Longa Linn) on the performance, egg yield, egg quality properties and blood parameters of hens(2019)
- The effect of bending temperature, holding time, thickness and bending angle on spring back of dual phased high strength steel sheets(2019)
- The rise of populism in liberal world order(2019)
- An evaluation of the performance of the management and development applications employed in wildlife development areas improvement area(2020)
