Abstract (EN)
Residual material properties of an industrial building exposed to fire were investigated experimentally in this study. Fire site was divided five part according to visual observation. Site investigation was the first stage of this study and second stage was the laboratory works which were made on steel and concrete core samples taken from industrial building columns. Concrete core samples were tested for residual mechanical properties by compressive strength test. Petrographic examination of cores was made with SEM (Scanning Electron Microscopy), XRD (X-ray Diffraction) and EDX (Energy Dispersive X-ray Spectroscopy) analysis. Reinforcement steel bars were investigated mechanically for tension strength. Mechanical and petrographic examination results were compared with the results in literature. Consequently, concrete lost mechanical, physical, and chemical properties with different deterioration ratios, and the possible temperature changes were between 100°C and 600°C in the industrial building during fire.
Author
Serkan Etli
How to Cite
Serkan Etli (Master Thesis). Residual material characteristics of an industrial building after fire, 2015, Gaziantep University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Gaziantep University
- Conceptual design methodology for foldable shelters(2019)
- Pilton (pastinaca armena) katkılı beyaz peynirin duyusal ve kimyasal özelliklerinin incelenmesi(2019)
- Constructions of popular culture within viral advertising: Reception analysis of Eti Benim'O virals(2021)
- Optimum usage of mixed damping systems (rubber concerete or x diagonal dampers) on multystory building(2021)
- Transcription and evaluation of Idrak newspaper(2021)
- Identification of allergenic proteins from Tilia cordata(2021)