Determining the effect of the ventilation system on thermal comfort in a standard room with radiant cooling system
Is this your thesis?
This record came from a bulk archive import. If it’s yours, link it to your profile.
Abstract (EN)
Basically, thermal comfort is based on energy balance between human body and an environment. Human body sweats when the environment is too hot. On the contrary case, human body shivers when the environment is too cold. For this reason, thermal comfort effects the quality of life in daily life. The calculation method of thermal comfort is based on PMV-PPD approach which was developed by Fanger in 1970. In heating and cooling conditions, radiant panel systems provide better thermal comfort than conventional systems. Ventilation systems are used with radiant panel systems to improve Indoor Air Quality and provide fresh air need. In this study, determining the effect of the ventilation system on thermal comfort with radiant cooling system is aimed. For this purpose, a standard room was designed whose floor area is 24 m2 and heigh 3.00 m. It has two interiors and two exterior walls. For this standard room, only radiant panel system without ventilation and radiant panel system which support by different ventilation types are analyzed with ANSYS - Fluent software. Ceiling ventilation which is located next to the window creates thermal protection curtain. Thus the ventilation system blocks the heat transfer from the window in to the room. Ceiling ventilation which is located next to the window with -16 W/m2 heat flux, mixing ventilation with -14 W/m2 heat flux, passive cooling with -18 W/m2 heat flux and -22 W/m2 heat flux were not found thermally comfortable according to the ASHRAE 55 and ISO 7730 standards. Ceiling ventilation which is located next to the window with 18 W/m2 heat flux and -20 W/m2 heat flux have the best thermal comfort values rather than others according to the ASHRAE 55 and ISO 7730 standards.
Author
Onur Oruç
Institution
How to Cite
Onur Oruç (Master Thesis). Determining the effect of the ventilation system on thermal comfort in a standard room with radiant cooling system, 2017, Yıldız Technical University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Yıldız Technical University
- A ruled-based software model in the preliminary design phase of housing: Example of Mardin(2008)
- An investigation on the relationship between problem solving and critical thinking skill, and academic achievement of vocational and technical high school students(2017)
- Numerical investigation of single bubble flow boiling both on a flat surface and on a cavity in horizontal pipe and pool boiling on a flat surface(2018)
- Examination of the categories in which buildings with LEED v3 and v4 certificates score the lowest points in Turkey(2018)
- Examining ?Historical housing structures" within the confines of protecting ecological balance(2012)
- A strategic approach in the context of developing urban quality; the conceptual model proposal of urban design guideline(2015)