Assessment of atmospheric particulate matter and precipitating dust pollution in industrial area of Van province
2019
0 görüntülenme
0 i̇ndirme
Danışman: Prof. Dr. Şükrü Dursun
Özet (EN)
In this study, both Turkish Standard methods and air quality modeling studies were carried out for PM10 and collapsed dust pollutants emitted from the ready-mixed concrete plant in Tusba, Van. Fistly dust sources were determined in the plant and their concentrations were examined at 3 points for PM10 and at 2 points for settled dust. In the measurements made according to the Turkish Standard methods, stock area, between two conveyor belts and bunker as well as PM10 concentrations are; 0.29 mg / Nm3, 0.98 mg / Nm3, 0.67 mg / Nm3. In the measurements made according to the Turkish Standard methods, the average concentrations of dust collapsed in the on-site roads and in the stock area in the first month were 50 mg / m2 / day and 151 mg / m2 / day, respectively. In the measurements carried out according to the Turkish Standard methods, mean concentrations of the 2nd month in the on-site roads and in the stock area are as follows; 68 mg / m2 / day, 163 mg / m2 / day. According to the results of AEORMOD modeling, stock area, and their annual concentrations are as follows between two conveyor belts, bunker as well as PM10 24-hour concentrations respectively; 8,91 µg / m3, 5,46 µg / m3, 6,77 µg / m3. It is 1,70 µg / m3, 0,60 µg / m3, 1,11 µg / m3. According to the results of AEORMOD modeling, the daily concentrations of dust deposited on the plant roads and in the stock area are as follows; 11.97 mg / m2 / day, 11.98 mg / m2 / day and annual concentrations respectively; 3.20 mg / m2 / day and 3.94 mg / m2 / day. When compared with the limit values set out in Annex-1 and Annex-2 of the Industrial Air Pollution Control Regulation, it is observed that the measured and calculated results are below the limit values.
Yazar
Dr. Şeyda Karaman
Bu Yayına Nasıl Atıf Yapılır
Şeyda Karaman (Master Thesis). Assessment of atmospheric particulate matter and precipitating dust pollution in industrial area of Van province, 2019, Konya Technical University.
Anahtar Kelimeler
Lisans
Tüm Hakları Saklıdır
Bu eser belirtilen lisans koşulları altında paylaşılmaktadır.
Konya Technical University tezlerinden daha fazlası
- Estimation of topographic density by bouguer anomalies and its effect on geoid determination(2022)
- Numerical and experimental in vestigation of optimization of Pelton turbine rotor design parameters in micro turbine size(2018)
- Controller design for a quadruped walking robot leg using the bees algorithm(2019)
- Determination of optimum frp composite amount in strengthening reinforced concrete beams with inadequate shear strength(2021)
- Modeling and optimization of a solar-wind hybrid microgrid with statcom(2021)
- Geomatic engineering activities and tunnel deformations in tunnel construction(2021)