A fire stopping product selection method for fire insulation of compartment barriers
2015
0 views
0 downloads
Advisor: Prof. Dr. Nihal Arıoğlu
Abstract (EN)
Dividing a building into fire resistant sections called "fire compartments" is an extensive passive protection measure. However it is necessary to make some openings onto fire separating elements enclosing fire compartments in order to install plumbing, electrical or mechanical equipment. Even a joint between adjacent building elements, a movement joint or joints to compensate some constructional imperfections might pass through a fire compartment. These joints and service openings are the weakest points of fire compartments whose essential function is to prevent fire from spreading across the building. Although the openings for service penetrations and joints seem negligible compared to the whole compartment barriers' surface area, they may contribute to the spread of fire through adjacent compartments and cause deaths as well as damages. In section 3. of the study, the openings on fire compartment barriers are grouped by orientation or by dimension. The openings may be horizontal (basically, the ones that are situated on floor slabs or ceilings) or vertical (the ones that are situated on vertical building elements such as walls) in terms of orientation. They may also be situated in between these two entities in the form of joints. On the other hand, the openings may be grouped by dimension too. In this case, they are not strictly separated from each other but they are limited by four overlapping dimension intervals: leakage openings, small openings, mid-sized openings, big openings. This grading system introduces a structured framework to analyse the case. The service openings and joints on fire barriers should be absolutely equipped with fire stopping products. These are used for helping fire separating building elements to regain their original fire resistance performance as required by regulations. Although there is already a quite wide range of firestops in the market today, new products which are more efficient, more easily applicable or more economical will be launched going forward as the producers invest in research and development. After a profound literature research and analysis of products supplied by six big companies from different parts of the World, the most common fire stops are classified in 17 groups as presented in section 4. Those products are sealants, brush grade sprayable mastics-paintings, foams, collars, wraps, bands, sleeves, putties, plugs, blocks, pillows, mortars, batts, vents, cavity barrier curtains, cast-in devices and strips. Lastly listed a backing material used for supporting some of these firestops. Analysing this much of firestop products from all around the World, the testing standards that producer companies use to demonstrate their products' performance are taken into consideration too. Most of them are analysed in section 4.1.5 . Fundamentally, the service penetrations and joints undergo different types of tests in both Europe and United States of America. Service penetrations are tested in full scale in laboratories, while only a section of joints can be tested in laboratories. The result of the tests in both America and Europe shows the time elapsed until the system fails to meet the minimum performance requirements. The performances measured by these tests are insulation and integrity functions of a system where a firestop product is installed. In case of a loadbearing system, the loadbearing capacity is added to performance requirements. Standards applied in United States of America and Canada have an additional request: to apply a hose stream test to measure resistance of the system, just after a fire incident, against pressurized water. Furthermore, voluntary tests evaluating water resistance or amount of air leakage through the test sample may be found on these standards Wide range of products, limited timing of design phase and insufficient number of expert on this subject makes it more and more complicated to choose the right product for a specific place. Especially the designers who are in charge of the coordination and control of the building phase may have difficulties to select the right firestopping product to ensure a complete fire resistance. This difficulty in selecting the right type of product may only be tackled by a systematic approach, which is the main objective of this study. In order to help the decision maker during the design phase, the study suggests a selection framework to find the most efficient firestop product providing a complete fire resistance and smoke proofing of service penetrations on the compartment wall/ floor for a required time. As the first step in this method, all of the firestop materials that may be purchased and transported to the construction site on time are listed. On consecutive sequences, selection system gradually sets performance requirements for firestop products. The ones that do not meet those requirements are eliminated. Right after defining all the possibilities, the elimination process begins as described in section 5.1.1 . The codes, standards, regulations and certification requirements of the respective country the construction takes place in, are thoroughly examined in this step. This may also show the amount of fire resistance time is required. In addition, if there is a special certificate requirement for the respective building, the additional requirements that the product needs to meet are listed as well. Firestops, which cannot meet such requirements, are eliminated. Building type is the next step for defining some other performance criteria, as described in section 5.1.2 . The building's fire hazard group would influence the selection of the firestop product. A building classified in extra hazard group may necessitate some extra measures compared to the ones in light hazard group. Additionally, the building's function may add some further requirements such as acoustical or anti-bacterial attributes. Similarly, some other attributes such as moisture resistance or air leakage resistance, etc. might be needed depending on the function of the room where the firestop will be applied, see 5.1.3 . In addition, the building element type is determinant of some further requirements, see 5.1.4 . The firestop product selected should be compatible with the material of the building element. Also the firestop material should be adaptable to the orientation and thickness of the building element. Finally, after the firestop material has been applied, the system as a whole should at least equal the fire resistance of the building element's own. Dimension and type of the opening will be affecting firestop selection as well. If there are multiple service penetrations or the space between the services is not in a straight geometrical shape, more fluid firestops may be selected in order to fill the opening between services. On the other hand, if the opening cannot be reached easily, the firestops with difficult installment process should be eliminated. Additionally, for a loadbearing opening or movement joint, a product with the capability of moving or loadbearing should be chosen. The service element type is the final criteria. Service elements may be combustive, moving or conducting electric. All of these properties have different performance requirements. Furthermore, if the service element melts at high temperatures reached during a fire, the respective firestops should be intumescent which increases their volume at the temperature causing the service element to melt. On the other hand, the firestops that reacts with the material of service elements should not be used. Also if the service element is not permanent or if the service element will be changed often during the building lifetime, firestops that can easily be removed and reapplied need to be preferred. Even after this detailed filtering process, there still can be more than one firestops left. In this case, there will be some further criteria including the affordability, the credibility of the producer, the installment time and the level of damage to health and environment. After this last step, the most effective product will be chosen, but still this should be checked via feedback. If there no problem is detected, a competent and educated group of workers should install the selected firestop product. In case there is still an opening left after the installment of the firestop, the selection system should be repeated again for that new opening until it is fully eliminated.
Author
Dr. İdil Tabak
Institution
How to Cite
İdil Tabak (Master Thesis). A fire stopping product selection method for fire insulation of compartment barriers, 2015, Istanbul Technical University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Istanbul Technical University
- Investigation Of Stretching Effect With Mixed Finite Element Formulations For Laminated Beams And Plates(2023)
- Classification of anemia using data mining methods: An application(2015)
- Removal and recovery of platinum group metals through anode slimes of moebius electrolysis(2015)
- A study of design approaches to Istanbul's city halls based on space syntax theory(2015)
- A II. German Empire project: From Kaiser Wilhelm Monument to German fountain(2015)
- Uzaktan algılama verilerinin yersel ölçümlerle entegrasyonu ile toprak tuzluluk haritalaması; Aşağı Seyhan Ovası, Adana, Türkiye(2015)