Effect of different marginal finish lines and marginal thickness on the fracture resistance of Zirconium reinforced lithium silicate glass ceramic crowns
Is this your thesis?
This record came from a bulk archive import. If it’s yours, link it to your profile.
Abstract (EN)
Aim: The aim of this study is to investigate the fracture resistance of zirconia reinforced lithium silicate glass ceramic (ZLS) crowns with different marginal finish lines and marginal thickness. Material and Method: The dies representing the prepared mandibular first molar tooth with a flat occlusal (non-anatomical) surface at 6 mm crown length and 6°taper angle, from which the specimens will be obtained, were prepared in the CAD/CAM milling unit to provide standardization. Specimens were separated into 8 groups as different marginal finish lines and marginal thickness. In the first group; 1 mm 135 ° shoulder finish line, in the second group; 1 mm 90 ° shoulder finish line, in the third group; 1 mm chamfer finish line, in the fourth group; 1 mm deep chamfer finish line, in the fifth group; 0,5 mm 135 ° shoulder finish line, sixth in the group; 0,5 mm 90 ° shoulder finish line, in the seventh group; 0,5 mm chamfer finish line, in the eighth group; 0,5 mm deep chamfer finish line. A total of 88 epoxy resin die models were obtained, 11 for each group, using silicone molds from these prepared dies. ZLS crowns were cemented with resin cement onto an epoxy resin die. The specimens thermocycled at 5-55 °C for 5000 cycles and then the fracture resistance test was performed with 1 mm/sec load speed by universal testing machine. Fractured specimens are grouped according to Burke classification fracture types. The fractured surfaces were examined in SEM (Scanning Electron Microscopy). The data were statistically evaluated using the Shapiro-Wilk, Oneway Anova tests. Results: Statistically significant difference was found between the groups (p=0,002; p<0.05). According to the data obtained in our study, ZLS crowns prepared as 1 mm chamfer finish line (1749.88±327.69 N) had the highest fracture strength values and ZLS crowns prepared as 0.5 mm 90° shoulder finish line (1030.91±432.84 N) had the lowest fracture strength values. Conclusion: It was concluded that different marginal finish lines and marginal thickness affect the fracture strength of ZLS crowns, 1 mm chamfer finish line design increases the fracture resistance of ZLS crowns. Key words: Chamfer finish line, Shoulder finish line, Fracture resistance, Zirconia-reinforced lithium silicate (ZLS)
Author
Elif Karakuş
Institution
How to Cite
Elif Karakuş (Dentistry Specialty Thesis). Effect of different marginal finish lines and marginal thickness on the fracture resistance of Zirconium reinforced lithium silicate glass ceramic crowns, 2022, Afyonkarahisar Health Sciences University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Afyonkarahisar Health Sciences University
- The association of non-traditional lipid profiles with ischemic stroke subtypes and recurrent stroke(2025)
- The effect of nursing support provided to primiparous pregnant women in labor on labor pain and delivery expectancy(2019)
- Evaluation of childhood lymphadenopathy cases(2023)
- Evaluation of different doses of hyaluronic acidadministration after arthrocentesis in patients withunreduced disc displacement: A randomised clinicaltrial(2024)
- Validation of vesical imaging-reporting and data system (VI-RADS) and its use in clinical management of bladder cancer(2024)
- Assessment of parental awareness and knowledge regarding the etiology and clinical findings of tongue thrusting(2025)
