Abstract (EN)

Industrial furnaces are the systems that consume the most energy in industrial facilities. Energy cost is the biggest input after raw material in systems with industrial furnaces. In industrial enterprises, annealing furnaces operating at high temperatures should be operated as efficiently as possible in terms of fuel consumption and reducing the pollution of waste gases to the environment. The increase in energy costs has made waste heat an important issue in energy management in industrial facilities. Systems such as economizer, recuperator, Organic Rankine Cycle (ORC) and Brayton cycle, and power cycles can be used to recover heat from waste heat and achieve significant energy savings. For the correct selection and proper operation of the systems, it is necessary to determine the places where the waste heat is located and to make energy and economic analyzes of the systems. In this study, energy analyzes of Brayton, Brayton-Rankine and ORC Cycles were carried out to provide power generation by utilizing the waste flue gas of an industrial annealing furnace in a flat structural steel production facility. In the analysis, the thermal efficiency of the system, the net power generation and the amount of CO2 that is prevented from being released into the atmosphere were calculated. All calculations in the analyzes were made with the help of the Engineering Equation Solver (EES) package program. In the analyzes, it was determined that the highest efficiency and power output belonged to the Brayton-Rankine combined power cycle after the annealing furnace, with a thermal efficiency of 46.64%, a net power of 3524 kW and an emission of 1555 kg-CO2 per hour. In the case of using n-pentane, cyclo-hexane and toluene fluids in the cycle of the ORC after the recuperator, it was seen that the most suitable fluid was cyclo-hexane. In the after recuperator ORC power cycle, 21.68% thermal efficiency, 518.2 kW power and 228 kg-CO2 per hour emission were obtained in the use of cyclo-hexane as the working fluid. The simple payback period for ORC power cycles after the Annealing Furnace recuperator has been calculated as 2.5 years.

Author

Buğra Kağan Sarpkaya

How to Cite

Buğra Kağan Sarpkaya (Master Thesis). Energy efficiency analysis in industrial reheating furnace, 2023, Harran University.

License

Tüm Hakları Saklıdır

This work is shared under the specified license terms.

More theses from Harran University