The purpose of this study is to analyse and compare stess distrubiton on bone screws and plate systems in locking and non-locking screw-plates design with two different size of lateral mandibular defects.Solid mathematical model of the mandible was created by three dimensional finite elements analysis and two different lenght lateral resection was performed on model. Models were reconstructed with two different reconstruction plate system including three 2.4 mm titanium screws. Then resected bone lenght varied. Realistic mastication force was applied by simulating natural muscles vectors. The effects of plate-screw types to the stress formation on bone and hard-ware systemwere evaluated and compared.The stress values of the cortical bone, plate and screw system of the conventional plate model was higher than the locking system model. The highest stress values were measured in the proximal segment especially in conjuction with convansional screw system. Furthermore, in use with locking system, the distribution of the stress on bone surface more homogeniously in both defect size. On the other hand in locking system, plates can subjected to much excessive force related with increasing defect size.In the use of standard reconstruction plate, the results of the finite element analysis revealed increased stress resulting from the simulated functional loadings. Possible clinical consequences could be loss of bone and gradual loosening of the osteosynthesis screws. Besides this, in large defect size a fatigue fracture of the plate itself can be occured by using locking system.On the bone surface, the amount of stress was less than conventional system and stress spreads wider area. It is evident that in the reconstruction model, the use of locking system offer an additional advantage over the conventional system particularly in small (25 mm) defects.
Author
Görkem Müftüoğlu
How to Cite
Görkem Müftüoğlu (Doctorate thesis). Evaluation of locking and non-locking reconstruction plate?SCREW SYStEM with lateral mandibular defects by fea, 2013, Başkent University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Başkent University
- Classification of aircraft images(2025)
- A nietzschean reading of cormac Mccarthy's Blood Meridian Or the Evening Redness in the west and The Road(2021)
- An analysis of the alignment of English textbooks in Turkish primary schools with the 21st century skills(2025)
- Competition law problems in the process of digitalization of financial services(2025)
- The gastronomic heritage of tradesmen's restaurants: The case of Ankara(2025)
- The impact of vocational education on the skilled labor shortage: A study on the construction sector in Ankara province(2025)