To climate a place, solar assisted ground source heat pump was designed. A water to water heat pump was selected because heating and cooling will be provided by using fan-coils. Hourly outdoor temperatures and hourly solar radiation values for Mardin city were obtained from Meteorology Management. Heat losses and gains were calculated hourly. While designing soil heat exchanger, vertical type was preferred because of horizontal pipe length?s being too long. Run factors were calculated using both Bin method and hourly method. Their results were compared. Solar energy system was used in two ways: direct heating and heating the water which returns to heat pump. Furthermore, multi cooling and heating (for four homes) was investigated by using same method. But for this time, the equipment of systems were redesigned and reselected. Finally, investment and operational costs of these two different systems were calculated. Also, costs for the same house calculated while using a boiler and chiller for heating and cooling. As a result, costs of these four different systems were compared. Keywords: Ground source heat pump, solar energy, run factor, cost analysis.
Author
Serkan Erdem
Institution
How to Cite
Serkan Erdem (Master Thesis). Economic analyses of solar assisted ground source heat pump in heating and cooling a house, 2007, Yıldız Technical University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Yıldız Technical University
- A ruled-based software model in the preliminary design phase of housing: Example of Mardin(2008)
- An investigation on the relationship between problem solving and critical thinking skill, and academic achievement of vocational and technical high school students(2017)
- Numerical investigation of single bubble flow boiling both on a flat surface and on a cavity in horizontal pipe and pool boiling on a flat surface(2018)
- Examination of the categories in which buildings with LEED v3 and v4 certificates score the lowest points in Turkey(2018)
- Examining ?Historical housing structures" within the confines of protecting ecological balance(2012)
- A strategic approach in the context of developing urban quality; the conceptual model proposal of urban design guideline(2015)