Yüksek LisansAçık Erişim

Bilgisayar simülasyonu ile membran biyoreaktör sisteminde enerji optimizasyonu için örnek çalışma: Konacık belediyesi

Bu tez size mi ait?

Bu kayıt toplu arşivden geldi. Sizinse profilinize bağlayın.

2012
0 görüntülenme
0 i̇ndirme

Özet (EN)

In this thesis, designing and operating conditions of existing treatment plant units compared to the results with ATV-DVWK-A 131 E standards for Konacık Municipality in Bodrum Domestic Wastewater Treatment. After then decreasing of energy consumption of the treatment plant was aimed and a computer simulation program (BioWin) was used for this purpose. In order to minimize the operational costs depending on energy consumption, two alternative operating strategies were generated by using BioWin program. At the end of the study, existing treatment plant operating data, results of calculations made considering ATV-DVWK-A 131 E standards, and results of the simulation program were compared. Existing design and operational conditions were confirmed according to ATV-DVWK-A 131 E standards and the most cost effective and appropriate operational condition considering effluent quality was determined.

Yazar

Servet Erol

Bu Yayına Nasıl Atıf Yapılır

Servet Erol (Master Thesis). Bilgisayar simülasyonu ile membran biyoreaktör sisteminde enerji optimizasyonu için örnek çalışma: Konacık belediyesi, 2012, Dokuz Eylül University.

Lisans

Tüm Hakları Saklıdır

Bu eser belirtilen lisans koşulları altında paylaşılmaktadır.

Dokuz Eylül University tezlerinden daha fazlası