In vitro evaluation of implant and peri-implant tissues different implant diameter, number and upper structure thickness variations for implant supported fixed prosthes regarding distribution by finite elemantal analysis method in patients with bruxism
2018
0 görüntülenme
0 i̇ndirme
Danışman: Doç. Dr. Sabiha Zelal Ülkü
Özet (EN)
The aim of this study is to evaluate use of monolithic zirconia ceramics in different occlusal thicknesses (1.0 mm, 1.5 mm, 2.0 mm) in implant fixed prosthetic restorations applied in bruxism patients with implants with diameter and number of variables and stresses in implant and surrounding tissues under vertical and oblique forces. In this study, a total of 4 titanium (Zimmer Biomet MTX Surface Tapered Screw-Vent Implant) implants of 3.7 mm, 4.1 mm, 4.7 mm and 6.0 mm in diameter were used. Three models were obtained by applying implants to the region between the 2nd premolar and the 2nd molar teeth of the mandibular model obtained from the tomographic records. The main model of Group 1 was created by implantation of 3.7 mm diameter implant in the premolar region and 4.7 mm diameter implant in the second molar region. The model of Group 2 was created by implanting 3.7 mm diameter implant in the premolar region, 4.7 mm diameter implant in the first molar region, and 4.7 mm diameter implant in the second molar region. The model of Group 3 was created created by implanting 4.1 mm diameter implant in the second premolar region and 6.0 mm diameter implant in the second molar region. The models formed were divided into 3 subgroups with occlusal thicknesses of 1.0 mm, 1.5 mm and 2.0 mm, forming a total of 9 groups. Stress distribution and stress values of implant, abutment, screw, implant-supported fixed prosthesis and bone in all models under vertical and oblique forces were investigated by finite elemental stress analysis method. As a result of our study, it was obsorved that increasing the diameter, number and occlusal thickness of the implant-supported fixed monolithic zirconia prosthesis in patients with bruxism was an effective factor in reducing the stresses on implants and components and supporting bone tissue.
Yazar
Dr. Yakup Kantaci
Bu Yayına Nasıl Atıf Yapılır
Yakup Kantaci (Dentistry Specialty Thesis). In vitro evaluation of implant and peri-implant tissues different implant diameter, number and upper structure thickness variations for implant supported fixed prosthes regarding distribution by finite elemantal analysis method in patients with bruxism, 2018, Dicle University.
Anahtar Kelimeler
Lisans
Tüm Hakları Saklıdır
Bu eser belirtilen lisans koşulları altında paylaşılmaktadır.
Dicle University tezlerinden daha fazlası
- Forensic medical examination of earthquake victims admitted to Dicle universi̇tesi Medical Faculty Hospitals as a result of the 6 february 2023 Kahramanmaraş centered earthquakes(2024)
- Human immunoglobulin G glication and its effect on antigen binding(2023)
- Resilience based design of rc buildings using seismic fragility analyses and a novel wall model(2023)
- Effects of some insecticides on biological characteristics of egg parasitoid Trichogramma evanescens Westwood (Hymenoptera: Trichogrammatidae) in pre- imaginal stages(2023)
- Effects of biorational insecticides on some biological features and functional response of the egg parasitoid trichogramma evanescens westwood (Hymenoptera: trichogrammatidae) exposed at differen pre-imaginal stages(2023)
- The role of financial architecture and institutional structure in growth and development: The example Diyarbakır(2023)