Evaluation of biocompatibility of four different one-step self etching adhesives by animal experimental method
2019
0 views
0 downloads
Advisor: Dr. Öğr. Üyesi Şeyhmus Bakır
Abstract (EN)
Aim: The success of materials used in dentistry is closely related to their biological safety. In recent years, there has been growing concern about the biocompatibility of self-etch adhesives, which are frequently used in restorative dental treatment. The aim of this study is; To compare the biocompatibility of four different single stage self-etch adhesive materials (Prime & bond one select, Optibond All-in-one, Clearfil universal bond, Single bond universal) with animal test method and evaluate them histopathologically. Materials and Methods: The experimental materials were polymerized by filling 10 mm long, 2mm diameter polyurethane tubes. For each adhesive, 21 tubes were used. The tubes were placed in the subcutaneous pockets formed by four different incisions in the back of 21 adult male albino rats. Rats; On the 7th, 30th and 60th days, they were randomly divided into three groups. At the end of these durations, the tube and the surrounding 2cm2 tissue were excised together. The sections were taken into preparation and stained with Hematoxylen&Eosin. The severity of inflammation, inflammatory cell count and fibrous capsule thickness were evaluted histopatologically by light microscopy. Results: On the 7th day samples, lesions due to acute inflammation and edema and PMNL infiltration were observed. In the 30th day samples, it was observed that inflammation decreased against all materials, and fibrocollagen tissue increased. On the 60th day, granulation and fibrous tissue increase due to regeneration and reperation processes were observed. On the 60th day, the number of inflammatory cells decreased significantly compared to the 7th day. When the fibrous tissue formation was evaluated, it was found that the 7th day score was significantly lower than the 60th day score. Conclusion: The severity of the inflammatory reaction at the beginning of all materials can be explained by the effect of residual monomer release and surgical trauma. Key Words: Self-etch adhesive, biocompatibility, animal testing
Author
Dr. Mehmet Salih Aydın
How to Cite
Mehmet Salih Aydın (Doctorate thesis). Evaluation of biocompatibility of four different one-step self etching adhesives by animal experimental method, 2019, Dicle University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Dicle University
- Resilience based design of rc buildings using seismic fragility analyses and a novel wall model(2023)
- Effects of some insecticides on biological characteristics of egg parasitoid Trichogramma evanescens Westwood (Hymenoptera: Trichogrammatidae) in pre- imaginal stages(2023)
- Effects of biorational insecticides on some biological features and functional response of the egg parasitoid trichogramma evanescens westwood (Hymenoptera: trichogrammatidae) exposed at differen pre-imaginal stages(2023)
- The role of financial architecture and institutional structure in growth and development: The example Diyarbakır(2023)
- Determination of neuromarkers associated with dementia using EEG and machine learning(2023)
- Retrospective analysis of liver hydatid cyst in children(2023)
