Comparison of shear bond strength of resin-modified glass ionomer to mineral trioxide aggregate with different surface pretreatment techniques
Is this your thesis?
This record came from a bulk archive import. If it’s yours, link it to your profile.
Abstract (EN)
Objective: The aim of this study was to evaluate the effects of different cavity disinfection methods on the bond strength of mineral trioxide aggregate (MTA) and glass ionomer cement (GIC) at 3 intervals after placement of MTA. Method: In current study, 180 cylindrical acrylic blocks, each of which had a hole (5 mm in diameter and 2 mm in height) in the middle were used. The samples were divided into three main groups on the basis of the intervals after placement of MTA. Main groups 1, 2 and 3 had intervals of 15 minutes, 24 hours and 72 hours respectively. All 3 groups were divided into 3 subgroups on the basis of the cavity disifection methods. Group A; chlorhexidine gluconate (CHX) (2mL/m, 2%), Group B; ozone (output power was 10), Group C; diode laser (810 nm, 1.5W, with 15-second cycle) and Group D was the control group. After all cavity disinfection methods were applied to all groups, GIC was applied with the aid of a 4 mm height 3 mm diameter flexible plastic tube on the MTA and cured immediately. After curing process, plastic tubes were removed. A universal testing machine was used for shear bond strength test. Shear bond strength in MPa was calculated by dividing the peak load at failure with the specimen surface area. Statistical analysis was performed. Results: Cavity disinfection with ozone and diode laser showed no significant differences according to the control group (P>0.05). CHX group showed significantly lower bond strength than the control group (P<0.05). There was no statistically significant difference between the intervals (15 m, 24 h, 72 h) after placement of MTA. Conclusion: In current study, CHX lowered the bond strength between MTA and GIC when used as a base material while ozone and diode laser had no negative effect. GIC can be successfully applied on MTA after a 15 min interval.
Author
Deniz Yanık
How to Cite
Deniz Yanık (Dentistry Specialty Thesis). Comparison of shear bond strength of resin-modified glass ionomer to mineral trioxide aggregate with different surface pretreatment techniques, 2018, Akdeniz University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Akdeniz University
- Numerical investigation of the notch effect in interference fit connections(2023)
- The purpose of present study was to determine the levels of situational anxiety caused by the pressure of the competitive situations exposed to by child athletes and to objectively evaluate the parameters of Heart Rate Variability (HRV) and state anxiety accompanying the change in emotional state.(2022)
- Proje tabanlı öğrenimin İngilizce hazırlık sınıfı öğrencilerinin konuşma yeterlilikleri ve iletişim kurma istekleri üzerine etkisi(2025)
- The formation of Medieval Islamic economic thought within the scope of East-West interaction(2024)
- A cost comparison of rubble mound breakwater with breakwater covered by antifer block(2018)
- Enderunlu Fazıl – Hûbân-nâme (Edition critique)(2024)
