In vitro assesment of bulk-fill composite resins in terms of conversion degree and microhardness
Is this your thesis?
This record came from a bulk archive import. If it’s yours, link it to your profile.
2018
0 views
0 downloads
Advisor: Prof. Dr. Nuray Attar
Abstract (EN)
The aim of this in vitro study was to evaluate bulk fill composite resins in terms of microhardness and conversion degree. In the study, 5 bulk fill composite resins [Filtek Bulk Fill Posterior (FB), 3M ESPE; Tetric EvoCeram Bulk Fill (TBF), Ivoclar Vivadent; SonicFill 2 Bulk Fill (SF), Kerr Co.; SDR Bulk Fill (SDR), Dentsply and Venus Bulk Fill (VB), Heraeus Kulzer] and 1 conventional composite resin [Filtek Ultimate (FU), 3M ESPE] were used. Teflon molds with a diameter of 6 mm and 1, 2, 3, 4 or 5 mm in height were prepared and composite resins were placed in these molds to prepare 30 samples (n = 6) for each composite resin in total 180 samples. Then, the bottom and top surface microhardness [Vickers hardness (HV)] values were determined. The conversion degrees (DC) were calculated by dividing the top surface to the bottom surface hardness value of the samples. DC and HV values were statistically evaluated using the Kruskal Wallis test and Dunn Sidak correction (p = 0.05). The highest top surface HV value at all thicknesses was measured on the SF group at 3 mm (116.52 ± 1.32 N / mm2), and the lowest bottom HV value was measured on the SDR group at 5 mm (37.78 ± 1.59 N / mm2) (p<0.05). The highest bottom surface HV value was measured on the SF group at 1 mm (109.41 ± 1.41 N/mm2), and the lowest bottom HV value was measured on the SDR group at 5 mm (33.47 ± 1.26 N/mm2) (p<0.05). DC % decreased with increasing thickness in all materials and VB group showed the highest DC % (97.07 %) at 1 mm thickness, FU showed the lowest DC (47.36 %) at 5 mm thickness (p<0.05). In this study, DC % were above the threshold value of 80 % in all the composite resin groups at 1, 2 and 3 mm thicknesses (p<0.05). In all groups, as thickness of the composite increased, the bottom surface HV values decreased and it was found that composite resin type affected HV and DC values.
Author
Cansu Sevik
How to Cite
Cansu Sevik (Dentistry Specialty Thesis). In vitro assesment of bulk-fill composite resins in terms of conversion degree and microhardness, 2018, Hacettepe University.
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Hacettepe University
- Elementler ve insan doğası arasındaki uyuşmazlık: Ekofobi ve Rönesans İngiliz tiyatrosu(2018)
- Gençlerin ve Gençlik Çalışanlarının Gözünden Gençlik Politikaları ve Hizmetlerinin Değerlendirilmesi(2022)
- Characterization of Ayvalik (Edremit yaglik) extra virgin olive oils volatile compounds with SPME-GC/MS and Raman spectroscopy(2018)
- A critical evaluation of pronunciation teaching in an ELT department in Turkey(2023)
- The effect of child labor related boycott threat on Ivory Coast cocoa production(2018)
- Neoliberalism and transformation of the state in Turkey: An analysis on the two-nations hegemonic project(2018)
