Investigation of the reliability of 4 different physical performance tests in patients with knee osteoarthritis
Is this your thesis?
This record came from a bulk archive import. If it’s yours, link it to your profile.
Abstract (EN)
Objective: To examine the reliability of 4 different physical performance tests in patients with knee osteoarthritis. Method: 38 individuals diagnosed with knee osteoarthritis were included in the study. The patients included in the study were asked to perform 2-minute walking test, L-test, Step test and tandem stance tests twice. Their reliability has been examined using ICC (2,1). SEM and MDC95 values were determined. Results: The ICC value for the 2-minute walk test was 0.99 (0.97-0.99), SEM and MDC95 values were 5.46 meters and 15.13 meters, respectively; the ICC value for the L-test is 0.99 (0.96-.099), SEM and MDC95 values are 1.37 seconds and 3.79 seconds, respectively; ICC value for the step test was 0.97 (0.92-.097), SEM and MDC95 values were 0.46 repetitions and 1.27 repeats, respectively; tandem stance test ICC value for position 1 is 0.99, SEM and MDC95 values are 0.02 seconds and 0.05 seconds, respectively; for position 2, the ICC value is 0.98, SEM and MDC95 values are 0.03 seconds and 0.08 seconds, respectively; for position 3, the ICC value was 0.89, SEM and MDC95 values were 0.09 seconds and 0.24 seconds, respectively. Conclusion: Four different physical performance tests, whose reliability was examined in our study, were found to be reliable in the evaluation of patients with knee osteoarthritis. We recommend the use of these 4 tests as complementary outcome measures for functional evaluation in patients with knee osteoarthritis. Keywords: osteoarthritis, reliability, 2-minute walk test, L-test, step test, tandem stance test.
Author
Abdurrahman Nalbant
Institution
How to Cite
Abdurrahman Nalbant (Doctorate thesis). Investigation of the reliability of 4 different physical performance tests in patients with knee osteoarthritis, 2020, Dokuz Eylül University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Dokuz Eylül University
- Analysis of speech clarity parameters in open plans offices(2021)
- The characteristic of rural architectural heritage and the conservation problem in Urla region(2019)
- AFAD gönüllülük sisteminin etkin müdahale açısından analiz(2020)
- Examination of martian habitats from the viewpoint ofstructure(2022)
- Environmental graphic design and public installation in the context of 21st century postmodernism(2022)
- Critics against Muawiyah ibn Abi Sufyan(2019)
