Medical SpecialtyOpen Access

Evaluation of relationship between used endobutone size and femoral channel enlargement at anterior cruciate ligament reconstruction

Is this your thesis?

This record came from a bulk archive import. If it’s yours, link it to your profile.

2018
0 views
0 downloads

Abstract (EN)

OBJECTIVE: In our study, patients who underwent arthroscopic anterior cruciate ligament reconstruction using autologous hamstring tendon autograft in Çanakkale Onsekiz Mart University Hospital, performed channel diameter measurements on the control AP and lateral radiographs of patients who had at least 2 to 3 years after surgery. MATERIALS AND METHODS: Between 2014 and 2018, 33 patients who underwent ACL reconstruction using the autologous hamstring graft and Endobutton® cortical suspension system were included in the study. Retrograde femoral bone tunnel enlargement was evaluated in postoperative 2nd and 3rd year control graphs. RESULTS: Of the 33 patients included in the study, 5 (15.2%) were female and 28 (84.8%) were male. The shortest follow-up period is 25 months and the longest follow-up period is 43 months, with an average follow-up of 29.5 months. There was no significant difference between the endobutton length and the femoral tunnel widths in the proximal, middle, and distal sections of the patients on the control graphs taken from the AP and lateral graphs. In the statistical study on the effect of graft diameter on enlargement, the femoral AP increases the canal diameter of the increase of the graft diameter in the middle part measurements (p: 0.009) and lateral distal position (p: 0.008). CONCLUSION: There was no significant difference between endobutton length and femoral tunnel widths. We believe the reason for this is that the endobutton hanger remains in the 4 mm narrow channel made with the first endobutton drill which in turn restricts movement. If the appropriate endobutton size is chosen, the windshield wiper effect is prevented so that the suspension can not be allowed to swing out of the narrow channel. As the graft diameter increases, the channel expansion rate also increases. We attribute this to the formation of greater osteonecrosis risk with larger drills. Key words:Arthroscopic ACL reconstruction, Bone tunnel enlargement, Endobutton size, Femoral tunnel enlargement, Hamstring tendon autograft.

Author

Ramazan Tıskaoğlu

How to Cite

Ramazan Tıskaoğlu (Medical Specialty Thesis). Evaluation of relationship between used endobutone size and femoral channel enlargement at anterior cruciate ligament reconstruction, 2018, Çanakkale Onsekiz Mart University.

License

Tüm Hakları Saklıdır

This work is shared under the specified license terms.

More theses from Çanakkale Onsekiz Mart University