Thermodynamic analysis of using R417A and R422D alternative refrigerant fluids in an air conditioning system working with R22
2019
0 views
0 downloads
Advisor: Prof. Dr. Vedat Oruç
Abstract (EN)
The goal of this survey is to empirical research the energy factors like refrigerating capability and performance coefficient (COP), by measurements with ozone-friendly refrigerants HFC-417A and HFC-422D (Hydrochlorofluorocarbons). Although there are studies about alternative refrigerants that can be used instead of HCFC-22 in the literature, there are no studies especially with small cooling capacity air conditioners and various refrigerants. An insulated duct is used in the system to keep the insulated room where the indoor unit is installed and the outdoor environment where the condenser operates at a constant temperature. A residential air conditioner system with a capability of 2.05 kW was used for the experiments. To measure temperature and pressure values, the thermocouple and the pressure transducer are located at the inlet and outlet of the condenser, the inlet of the compressor, the inlet of the expansion valve, and the outlet of the evaporator. Mass flow ratio was evaluated with a flow meter. The measurements were repeated for each refrigerant. In addition, the temperatures of the outside and insulated rooms were measured. Compressor power meter was used to measure electricity consumption. Error analysis was performed to determine the accuracy of the measurements. Cooling capacity, energy consumption and COP values were calculated. Experimental results were analyzed and evaluated in detail. The energy parameters of the system are obtained and the measurements obtained for each gas are presented on the same graph for comparison between each other. It has been determined how system energy parameters change according to gas types. A wide analysis and interpretation of the results indicated in the graphs were made. The findings of the study are expected to be a useful resource for research and design in the field of refrigeration and air conditioning.
Author
Dr. İbrahim Vural
How to Cite
İbrahim Vural (Master Thesis). Thermodynamic analysis of using R417A and R422D alternative refrigerant fluids in an air conditioning system working with R22, 2019, Dicle University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Dicle University
- Resilience based design of rc buildings using seismic fragility analyses and a novel wall model(2023)
- The role of financial architecture and institutional structure in growth and development: The example Diyarbakır(2023)
- Determination of neuromarkers associated with dementia using EEG and machine learning(2023)
- Forensic medical examination of earthquake victims admitted to Dicle universi̇tesi Medical Faculty Hospitals as a result of the 6 february 2023 Kahramanmaraş centered earthquakes(2024)
- STEAM in geography education and sample applications(2024)
- Determination of forage quality characteristics of some trigonella genotypes growing in meadow-pasture and natural vegetation of southeastern anatolia region(2024)