In vitro study of marginal and internal fit of ceramic crowns with cobalt-chromium and titanium metal frameworks produced by cCAD / CAM and conventional casting methods
Is this your thesis?
This record came from a bulk archive import. If it’s yours, link it to your profile.
Abstract (EN)
Metal-ceramic restorations are the most common type of fixed prosthesis that is used clinically. Due to the high cost of precious metal alloys, high biocompatibility, resistance to corrosion, low thermal conductivity and low density compared to base metal alloys of titanium have increased the popularity of titanium alloys and their use in dentistry in recent years. The use of computer technologies such as advancing and subtracting in dentistry has also changed the production technique of metal substructure restorations prepared by casting methods. Metal substructures produced with different production methods affect marginal and internal compatibility of restorations. The purpose of this study is; The evaluation of the marginal and internal consistencies of the cobalt chromium and titanium substructured ceramic crowns produced by the CAD / CAM method and conventional method. In vitro experiments were performed on the micro-CT device with silicone replica method to evaluate the fit of the experimentally prepared single crowns. According to the obtained results, there was no statistically significant difference between marginal range values of CoCr casting, CoCr milling, Ti casting, Ti milling groups. While there was no statistically significant difference between CoCr milling groups and CoCr milling groups in the axial region of the internal interspace, the difference between Ti casting and Ti milling groups was found to be statistically significant. The highest value in the axio-occlusal corner area in the internal range was observed in the Ti milling, Ti casting and CoCr casting groups respectively in the CoCr milling group. These differences between the groups were statistically significant. The highest value in the occlusal field area in the internal range was seen in the CoCr milling group. It was observed in Ti casting, CoCr casting and Ti milling groups respectively. These differences between the groups were statistically significant. The lowest value among the internal range volume values was observed in the Ti milling group and then in the CoCr casting, CoCr milling and Ti casting groups respectively. These differences among the groups were found statistically significant except CoCr casting group. Key words: Titanium milling; CoCr milling; CoCr cast; Titanium cast, marginal and İnternal fit; internal volume values
Author
Kutay Gürel
Institution
How to Cite
Kutay Gürel (Doctorate thesis). In vitro study of marginal and internal fit of ceramic crowns with cobalt-chromium and titanium metal frameworks produced by cCAD / CAM and conventional casting methods, 2018, Ege University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Ege University
- Increasing the fertilization yield of trout eggs(2013)
- The investigation of colorimetric capnometry events in the correct placement of nasogastric tube(2015)
- Effect of self-efficacy of children and adolescents with asthma on their quality of life(2015)
- Two "Âşık" in the city environment: Maksut Koca and Nevruz Ali̇ Çi̇çek(2015)
- Blood use standardization according to risk score on congenital heart surgery(2015)
- Effect of microfibers on mechanical and durability properties of cement mortar mixtures(2015)