Analytical performance evaluation of Siemens Sysmex CS–2500 and Abbott CP–3000 devices
2020
0 görüntülenme
0 i̇ndirme
Danışman: Dr. Öğr. Üyesi Özgür Mehmet Yis
Özet (EN)
Aim: Hemostasis tests are requested by clinicians for many purposes such as screening, diagnosis, and drug monitoring. Automatic coagulation devices have been used in the last 50 years and have been seriously developed. The diversity of the methods, kits and devices used, and being influenced by many preanalytical factors made standardization difficult in these tests. One of the most basic methods for standardization is method comparison. In this study, it was aimed to evaluate analytical performances of CS–2500 and CP–3000 devices and to compare methods. Material and Method: Reference interval verification study, precision, trueness evaluation and method comparison study were performed for APTT, PT and D–dimer tests. IQC were used for precision assessment, EQC samples were used for trueness assessment. Samples from 220 patients were used for reference interval validation and method comparison study. In evaluating precision and trueness, % CV and % bias values were calculated. In the comparison study, Blant – Altman, Passing – Bablok regression analysis and correlation coefficient were used. All studies were carried out in accordance with CLSI protocols. Results: The calculated% CV values for APTT and PT in both devices were below 5%, which is the CLSI recommendation. D–dimer reagents meet the quality criteria recommended by CLSI. Trueness is within acceptable limits on both devices. The reference ranges suggested by the manufacturer are verified. Regression equations for APTT, PT and D–dimer were found as y = –3,313 + 1,188, y = –0,0399+ 1,048 x, y = 0,155 + 0,655 x, and r values were 0,904, 0,978, 0,974, respectively. Conclusion: CS–2500 and CP–3000 devices measure with sufficient trueness and precision. In the method comparison study, there are measurement differences as different reagents are used between the devices, but they are generally acceptable. Both devices are suitable for use in laboratories for routine coagulation. It is important to standardize the results for coagulation tests. Since the CP–3000 device has recently been used in our country, it must be supported by comparison studies.
Yazar
Dr. Mine Büşra Pehlivan
Bu Yayına Nasıl Atıf Yapılır
Mine Büşra Pehlivan (Medical Specialty Thesis). Analytical performance evaluation of Siemens Sysmex CS–2500 and Abbott CP–3000 devices, 2020, Bolu Abant Izzet Baysal University.
Anahtar Kelimeler
Lisans
Tüm Hakları Saklıdır
Bu eser belirtilen lisans koşulları altında paylaşılmaktadır.
Bolu Abant Izzet Baysal University tezlerinden daha fazlası
- In social studies students and teachers opinions on the training of cultural heritage(2014)
- The relationship between emotional intelligence, marital satisfaction, and religiosity in married individuals(2024)
- Echocardiographic evaluation of right ventricular function in patients with coronary slow flow(2023)
- A review of the trajectory of teaching the history of science in social studies and other textbooks(2023)
- Gerund in Kumuk Turkish(2025)
- An example of the charitable women sultans of the Ottoman Empire: Hurrem Sultan(2019)