Evaluation of the success of current adhesive systems in bonding to caries affected dentin
Is this your thesis?
This record came from a bulk archive import. If it’s yours, link it to your profile.
Abstract (EN)
Objective: To evaluate the long-term bonding success of sound and caries-affected dentin using universal adhesives by microtensile bond strength test, electron microscopy (SEM) and confocal laser scanning microscopy (CSLM) images to be taken from resin-dentin interfaces. Material and Method: In this in vitro study, a total of 120 sound and decayed human molar teeth were extracted using a manual excavator until soft caries lesions reached a hard dentin layer, and a flat surface was created by reducing the dentin level with a precision cutting device. With the Vickers microhardness test, the surface microhardness was determined by applying a 25 g load for 15 seconds, and the sound and caries-affected dentin samples were divided into 3 subgroups (sound dentin-SD, caries-affected superficial dentin-D1 and caries-affected deep dentin-D2). Dentin samples were divided into 4 subgroups for each group and adhesive systems were applied; Group 1: Peak Universal Bond (Ultradent)+self-etch mod, Group 2: Peak Universal Bond (Ultradent)+etch and rinse mode, Group 3: G-Premio Bond (GC)+self-etch mode, Group 4: G -Premio Bond (GC) )+etch and rinse mod. A nanohybrid universal resin composite structure was prepared on the samples. Hourglass shaped slabs kept in 37 C0 distilled water were cut off at 1 mm/min head speed in a universal test device for microtensile bond strength (μTBS) test after 24 hours and 1 year, and the fracture types were evaluated with a stereomicroscope at 25x magnification, with a SEM and CSLM of the resin-dentin interfaces. One-way analysis of variance (One-way ANOVA), Scheffe multiple comparison test and independent t-test were used for statistical analysis, and the level of significance was determined as p≤ 0.05. Results: After 24 hours, the highest bond strength value was recorded in the SD group at PUB-SE (36.80 MPa), the lowest value in the D1 group at G-PB SE (17.60 MPa). After 1 year, the highest bond strength value was recorded in the SD group at G-PB SE (30.38 MPa), the lowest value in the D1 group at PUB SE (16.67 MPa). Conclusion: It was observed that the bond strength of universal adhesives to caries-affected dentin was significantly lower compared to sound dentin, a significant difference was observed between different modes of application, and the Vickers test was an effective method to distinguish between sound and caries-affected dentin. Key words: caries-affected dentin, microhardness, universal adhesive, microtensile bond strength, confocal laser microscopy.
Author
Nurgül Çetin Tuncer
How to Cite
Nurgül Çetin Tuncer (Dentistry Specialty Thesis). Evaluation of the success of current adhesive systems in bonding to caries affected dentin, 2022, Akdeniz University.
Keywords
License
Tüm Hakları Saklıdır
This work is shared under the specified license terms.
More theses from Akdeniz University
- Numerical investigation of the notch effect in interference fit connections(2023)
- The purpose of present study was to determine the levels of situational anxiety caused by the pressure of the competitive situations exposed to by child athletes and to objectively evaluate the parameters of Heart Rate Variability (HRV) and state anxiety accompanying the change in emotional state.(2022)
- Proje tabanlı öğrenimin İngilizce hazırlık sınıfı öğrencilerinin konuşma yeterlilikleri ve iletişim kurma istekleri üzerine etkisi(2025)
- The formation of Medieval Islamic economic thought within the scope of East-West interaction(2024)
- A cost comparison of rubble mound breakwater with breakwater covered by antifer block(2018)
- Enderunlu Fazıl – Hûbân-nâme (Edition critique)(2024)
